Stered solutions

Firing range Detva – soundproofing firing range 2015

Assignment:
Acoustic preparation firing range placed in an enclosed building. The requirement to reduce noise propagation in space in an enclosed building.
Used solution:
Wall and ceiling acoustic insulation STERED ID 200/050, 150/050 STERED ID and ID STERED 200/080. Cladding was drawn substitution.
Result:
Reduce noise transmission into the environment. Achieve the satisfaction of the client.




Apartment House – soundproofing boiler 2015

Assignment:
Acoustic preparation before boiler installation of heat pumps. The requirement to reduce vibration attenuation.
Used solution:
Wall and ceiling adjacent room sound insulation STERED ID 200/050.
Result:
Reduce vibration and noise transmission to surrounding rooms. Reached compliance with the standards.




Production factory for filters in air conditioners Trenčín – Quiet and Anti-Vibration shearing machine.

Assignment:
The vibration transmission damping and sound insulation foundations press fairing shearing machine.
Used solution:
Use vibration mats CONIRAP 0.1 S 50 to odvibrovanie foundation machine and soundproofing.
Result:
Reduce vibration and noise transmission to the production center. Reached compliance with the standards.




Industrial building (Finishing of a building of Systemair – Kalinkovo) 2014

Assignment:
On the roof of the office building SO5 around stationary noise sources must be installed noise barriers with sound reduction min. Rw = 35 db
Used solution:
Soundproof wall LPHS STERED made of steel “C-cassette” the minimum thickness of steel is 0.75 mm, powder coated with PE and acoustic panels STERED ID, thickness 80 mm, bulk density 200 kg / m3, on inside side with laminating glass or PP Vlies, from the outside primed with AKRYMAL to increase resistance to the spread of fire. Steel profiles are sealed in connectings with cellular rubber tape3x9 mm. STERED plate is inserted into the cartridge C laminated side down.
Result:
Reduction of the noise level for the desired value. There has been compliance with the standard.




Firing range 2014

Assignment:
Reducing noise echoes – Shooting Range
Used solution:
Setting acoustic panels STERED
Result:
Reaching nearly zero sound reverberation from shooting in space of firing range.




Industrial building (Volkswagen – New scrap yard, Bratislava) 2013

Assignment:
Reducing noise leakage into the outside environment
Used solution:
Setting on the inner part of outer walls with acoustic absorption panels STERED ID 200/050 KF (with increased sound insulation Rw = 27 dB)
Result:
Reduction in noise level outdoors, – 27 dB compared to internal noise




Industrial building (Dipex, Sered) 2013

Assignment:
Reduction of diffuse noise in the interior – working environment.
Used solution:
Acoustic absorption panels STERED ID 200/050 F6
Result:
Reduction of diffuse noise in the production area for at least 4 dB. There has been compliance with the standard.




Industrial building no. 4 (PR Krajné) 2013

Assignment:
Reduction of diffuse noise in the interior – working environment.
Used solution:
Acoustic absorption panel STERED ID 200/050 F6. Setting the inner parts of the outer walls with acoustic absorption panels STERED ID 200/050 + STERED S 060
Result:
Reduction of diffuse noise in the production area for at least 4-11 dB. There has been compliance with the standard.